<LOGO>
FM Transmitter Measurement Report
Created: 2026-10-01 10-35-17
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 70 kHz 15126 11,4968
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,3 dBr 4,93 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 70 kHz MIN: 11 kHz % above 76 kHz: 11,4968 Acquired: 2026.10.01 10.34.14 Total samples: 15126 Equivalent time: 0:12:36 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,3 dBr MIN: 2,3 dBr AVE: 4,93 dBr % above 12,2 dBr: 0,0 Last value: 3,9 dBr (2026.10.01 10.34.14) 10.20 10.22 10.24 10.26 10.28 10.30 10.32 10.34 0 2 4 6 Pm [dBr]